WEKO3
アイテム
Clinical Significance of Cough Peak Flow and Its Non-Contact Measurement via Cough Sounds: A Narrative Review
https://hcu.repo.nii.ac.jp/records/188
https://hcu.repo.nii.ac.jp/records/1883e376b25-6109-4847-881e-6049bb2102d4
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2023-03-14 | |||||
タイトル | ||||||
タイトル | Clinical Significance of Cough Peak Flow and Its Non-Contact Measurement via Cough Sounds: A Narrative Review | |||||
言語 | en | |||||
タイトル | ||||||
タイトル | Clinical Significance of Cough Peak Flow and Its Non-Contact Measurement via Cough Sounds: A Narrative Review | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | cough | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | cough peak | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | flow | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | cough strength | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | cough sounds | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | mobile device | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Coughing is the primary defence mechanism against foreign bodies in the central airways and can quantitatively be assessed by cough peak flow (CPF). We conducted a narrative review of the literature on CPF, which is most commonly used for evaluating cough strength. This review regards the method for measurement of CPF, the cough-related factors influencing CPF, the clinical significance of CPF evaluation, and a novel cough strength prediction method using cough sounds. Furthermore, this review presents various cutoff thresholds that predict extubation failure in patients on mechanical ventilation, acute respiratory failure, and aspiration risk. The published clinical evidence of CPF demonstrates reasonable diagnostic accuracy, predictive power, and validity, although additional studies on the non-contact measurement of CPF via cough sounds with better-quality methodologies are required. | |||||
書誌情報 |
Applied Sciences 巻 10, 号 8, p. 2782(1)-2782(12), 発行日 2020-04-17 |
|||||
出版者 | ||||||
出版者 | Molecular Diversity Preservation International | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 20763417 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | info:doi/10.3390/app10082782 | |||||
権利 | ||||||
権利情報 | (C)Molecular Diversity Preservation International | |||||
他の資源との関係 | ||||||
関連名称 | https://www.mdpi.com/2076-3417/10/8/2782 | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
日本十進分類法 | ||||||
主題Scheme | NDC | |||||
主題 | 493.3 |